{"id":13965,"date":"2016-05-26T21:31:36","date_gmt":"2016-05-26T21:31:36","guid":{"rendered":"http:\/\/www.iacdrive.com\/2016\/05\/26\/industrial-ethernet-vs-fieldbus-technologies\/"},"modified":"2016-05-26T21:31:36","modified_gmt":"2016-05-26T21:31:36","slug":"industrial-ethernet-vs-fieldbus-technologies","status":"publish","type":"post","link":"http:\/\/iacdrive.com\/?p=13965","title":{"rendered":"Industrial Ethernet vs. Fieldbus technologies"},"content":{"rendered":"<p>Where we really need digital communication networking, in my personal opinion, is down at the sensor\/transmitter and positioner\/actuator\/valve level to take the place of 4-20 mA and on\/off signals. Down at the level 1 of the Purdue reference model you need a fieldbus, not one of the &#8220;H2&#8221; types of fieldbus, but one of the &#8220;H1&#8221; types of fieldbus. When first introduced, these technologies were not as fast and not as easy to use has they could have been, but after many years of refinement these technologies are finally becoming sufficiently easy for most plants to use.<\/p>\n<p>An &#8220;H1 fieldbus&#8221; is the most practical way to digitally network sensors\/transmitters and positioners\/actuators\/valves to the DCS. Options include FOUNDATION fieldbus H1, PROFIBUS-PA, CompoNet, ASI, and IO-link. These protocols can take the place of 4-20 mA and on\/off signals.<\/p>\n<p>Note that &#8220;H1 fieldbus&#8221; should not be confused with the very different &#8220;H2 fieldbus&#8221; category of protocols used at level 1-1\/2 of the Purdue reference model to connect remote-I\/O, <a target=\"_blank\" href=\"http:\/\/www.iacdrive.com\".\n\n\nBecause H1 and H2 are distinctly different in many ways, they should not be lumped together as just \"fieldbus\". With this in mind it is easy to see that both Ethernet and fieldbus will grow for decades to come\n\n\nSo Ethernet may become a dominant network technology at level 1-1\/2 of the Purdue reference model but since Ethernet is not a good fit for level 1 of the Purdue model we don't see Ethernet in sensors and actuators out in the field. For example, pressure, temperature, level, vortex flow, interface level, pH, conductivity, or DO2 transmitter or control valve positioner or on\/off valve etc. are not available with Ethernet.\n\n\nIn my personal opinion, the industry can't move forward using 4-20 mA and on\/off signals. Modern plants need many more sensors than plants of the past to feed the \"big data\" paradigm but also for real-time data for equipment reliability, energy conservation, and improved HS&amp;E; maybe 2X or 3X \u2013 just like in a modern car vs. a car of the past. Using 4-20 mA and on\/off signals for all these sensors is just impractical. We need digital communication from the very \"first meter\". Just like a modern car has digital communication network for all the sensors (in fact multiple networks for different functions); so should a plant have digital sensor networks too: \"H1 fieldbus\" as well as wireless sensor networks too.\n\n\n\"H1 fieldbus\" will grow and this will generate more data from the sensors\/transmitters and positioners\/actuators\/valves at level 1 of the Purdue reference model which in turn will drive increased use of Ethernet at the higher level networks at level 1-1\/2 and above of the Purdue model.\n\n\nHow \"H1 fieldbus\" complements Ethernet can be seen in how IO-Link was created after PROFINET to support the architecture at level 1 of the Purdue reference model, and how CompoNet was created after EtherNet\/IP to support the architecture at level 1 of the Purdue reference model.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Where we really need digital communication networking, in my personal opinion, is down at the sensor\/transmitter and positioner\/actuator\/valve level to take the place of 4-20 mA and on\/off signals. Down at the level 1 of the Purdue reference model you need a fieldbus, not one of the &#8220;H2&#8221; types of fieldbus, but one of the &#8220;H1&#8221; types of fieldbus. When first introduced, these technologies were not as fast and not as easy to use has they could have been, but after many years of refinement these technologies are finally becoming sufficiently easy for most plants to use.<\/p>\n<p>An &#8220;H1 fieldbus&#8221; is the most practical way to digitally network sensors\/transmitters and positioners\/actuators\/valves to the DCS. Options include FOUNDATION fieldbus H1, PROFIBUS-PA, CompoNet, ASI, and IO-link. These protocols can take the place of 4-20 mA and on\/off signals.<\/p>\n<p>Note that &#8220;H1 fieldbus&#8221; should not be confused with the very different &#8220;H2 fieldbus&#8221; category of protocols used at level 1-1\/2 of the Purdue reference model to connect remote-I\/O, <a target=\"_blank\" href=\"http:\/\/www.iacdrive.com\".\n\n\nBecause H1 and H2 are distinctly different in many ways, they should not be lumped together as just &#8220;fieldbus&#8221;. With this in mind it is easy to see that both Ethernet and fieldbus will grow for decades to come\n\n\nSo Ethernet may become a dominant network technology at level 1-1\/2 of the Purdue reference model but since Ethernet is not a good fit for level 1 of the Purdue model we don&#8217;t see Ethernet in sensors and actuators out in the field. For example, pressure, temperature, level, vortex flow, interface level, pH, conductivity, or DO2 transmitter or control valve positioner or on\/off valve etc. are not available with Ethernet.\n\n\nIn my personal opinion, the industry can&#8217;t move forward using 4-20 mA and on\/off signals. Modern plants need many more sensors than plants of the past to feed the &#8220;big data&#8221; paradigm but also for real-time data for equipment reliability, energy conservation, and improved HS&amp;E; maybe 2X or 3X \u2013 just like in a modern car vs. a car of the past. Using 4-20 mA and on\/off signals for all these sensors is just impractical. We need digital communication from the very &#8220;first meter&#8221;. Just like a modern car has digital communication network for all the sensors (in fact multiple networks for different functions); so should a plant have digital sensor networks too: &#8220;H1 fieldbus&#8221; as well as wireless sensor networks too.\n\n\n&#8220;H1 fieldbus&#8221; will grow and this will generate more data from the sensors\/transmitters and positioners\/actuators\/valves at level 1 of the Purdue reference model which in turn will drive increased use of Ethernet at the higher level networks at level 1-1\/2 and above of the Purdue model.\n\n\nHow &#8220;H1 fieldbus&#8221; complements Ethernet can be seen in how IO-Link was created after PROFINET to support the architecture at level 1 of the Purdue reference model, and how CompoNet was created after EtherNet\/IP to support the architecture at level 1 of the Purdue reference model.<\/p>\n","protected":false},"author":0,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[67],"tags":[],"class_list":["post-13965","post","type-post","status-publish","format-standard","hentry","category-iacdrive_blog"],"_links":{"self":[{"href":"http:\/\/iacdrive.com\/index.php?rest_route=\/wp\/v2\/posts\/13965","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/iacdrive.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/iacdrive.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"http:\/\/iacdrive.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13965"}],"version-history":[{"count":0,"href":"http:\/\/iacdrive.com\/index.php?rest_route=\/wp\/v2\/posts\/13965\/revisions"}],"wp:attachment":[{"href":"http:\/\/iacdrive.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13965"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/iacdrive.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=13965"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/iacdrive.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=13965"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}